Q: Identify the Incorrect statement with respect to shear strength of bolts.
A.
Shear capacity reduction factor for packing plates is applied when packing plates more than 6 mm in thickness.
B.
The shearing strength of a bolt can be maximum in double shear.
C.
Shear capacity reduction factor for long joints is applied when length of joint exceeds 15 times the nominal diameter of bolt.
D.
Shear capacity reduction factor for large grip lengths is applied if the total thickness of connected plates exceeds three times the nominal diameter of bolt.
Correct Answer:
Option D -
Explanations:
Download Our App