Q: Calculate the net area of the tension member consists a drilled hole of diameter 22 mm to place a M20 bolt. Take thickness of the tension member as 10 mm and gross area 1000 mm².
A.
680 mm²
B.
780 mm²
C.
1000 mm²
D.
550 mm²
Correct Answer:
Option B -