Correct Answer:
Option A - As per IS 800 : 2007, Clause F-3.1, where the ends of compression members are faced for bearing over the whole area, they shall be specified to hold the concentrated part aligned.
• Clause 12.5.2.1, A partial joint penetration groove weld may be provided in column splice, such that the design strength of the joints shall be at least equal to 200% of the required strength.
• A column splice is used to increase length of the column.
A. As per IS 800 : 2007, Clause F-3.1, where the ends of compression members are faced for bearing over the whole area, they shall be specified to hold the concentrated part aligned.
• Clause 12.5.2.1, A partial joint penetration groove weld may be provided in column splice, such that the design strength of the joints shall be at least equal to 200% of the required strength.
• A column splice is used to increase length of the column.