Correct Answer:
Option B - IS : 456-2000, Clause 23.2,
(a) The final deflection due to all loads including the effects of temperature, creep and shrinkage and measured from the as-cast level of the supports of floors, roofs and all other horizontal members, should not normally exceed span/250.
(b) The deflection including the effect of temperature creep and shrinkage occurring after erection of partitions and the application of finishes should not normally exceed span/350 or 20 mm which ever in less.
B. IS : 456-2000, Clause 23.2,
(a) The final deflection due to all loads including the effects of temperature, creep and shrinkage and measured from the as-cast level of the supports of floors, roofs and all other horizontal members, should not normally exceed span/250.
(b) The deflection including the effect of temperature creep and shrinkage occurring after erection of partitions and the application of finishes should not normally exceed span/350 or 20 mm which ever in less.