search
Q: As per IS 800 : 2007, what is the maximum pitch of bolts allowed in a lap joint between two steel plates (in compression) of equal of thickness, t?
  • A. 12t or 200 mm whichever is less
  • B. 2.5 times diameter of the hole
  • C. 2.5 times diameter of the bolt
  • D. 16t or 200 mm whichever is less
Correct Answer: Option A -
answer image

Explanations:

explanation image