Explanations:
According to IS 800 : 2007– (a) Pitch 'P' shall not be less than 2.5d where 'd' is the nominal diameter of bolt. (b) Pitch 'P' shall not be more than (i) 16t or 200 mm whichever is less, in case of tension members. (ii) 12t or 200 mm, whichever is less in case of compression member where, t is the thickness of thinnest member.