search
Q: A town has a projected population of 80,000 spread over an area of 0.6 km2. Find the design discharge for the separate sewer line by assuming rate of water supply of 200 litre/capita/day and out of this total supply only 75% reaches in sewer as waste water. Assume a peak factor of 2.
  • A. 0.14 m3/S
  • B. 0.07 m3/S
  • C. 0.28 m3/S
  • D. 0.56 m3/S
Correct Answer: Option C -
answer image

Explanations:

explanation image